Key Benefits
- Meets Part E of the Building Regulations
- Achieves 1hr fire rating
- Takes screws and nails direct
- Minimal thickness
- Extremely durable and robust
- Suitable for new build projects
- Suitable for domestic, commercial and industrial projects
Maxiboard is an extremely high performance and versatile acoustic building board. Maxiboard can be used to dramatically increase the acoustic performance of both existing and newly constructed walls and ceilings. The Maxi Beam and Block Ceiling system is ideal in situations where Building Regulations Part E compliance is required along with a 1 hour fire separation. Simply installed below the Rackham Housefloors beam and block floor, the Maxi Beam and Block ceiling system minimises loss of room height.
Acoustic Performance:
Maxi Beam and Block Ceiling | |||
Airborne | Impact | ||
DnT,w | DnT,w+Ctr | L'nT,w | |
Maxi Beam and Block Ceiling | 51 | 47 | 52 |
Acoustic tests carried out by SRS Ltd in accordance with BS EN ISO 140 parts 4 and 7. Rated to BS EN ISO 717 parts 1 and 2. Test references EXET03-04
Fire performance:
Maxi Beam and Block | Loadbearing Capacity | Integrity | Insulation |
Fire Resistance BS EN 1365-2: 2000 | 132 minutes | 132 minutes | 132 minutes |
Fire resistance tests carried out 21/12/2004 by Warrington Fire Research Centre. WFRC Test Report No 143085
For full installation guidance, acoustic data and product specifications, please download the Maxi Beam and Block Ceiling Specification datasheet. If you are unable to find the information you need, please email your query to info@soundreduction.co.uk or call 01204 380074 for further assistance.
If you would like a quotation please contact our sales department using the button below for prompt assistance.
Request a quoteIf you would like a sample of any of our products please access the sample request form using the button below.
Request a sampleOur professional, Institute of Acoustics registered technical department is on hand to give advice on all of our high performance acoustic products. We're delighted to offer advice on any noise problem, be it a sound insulation or sound absorption issue.
* Please note that all calls are recorded for training and quality control purposes. If it is not possible to answer your call, please leave a message and your contact details on the answer phone, and an advisor will get in touch as soon as possible.